Objective: To demonstrate and evaluate THERMO, a thermal-velocity optimization algorithm for autonomous electrosurgery, in ex vivo porcine tissue using the UR10e-based ASTR system. Methods: Thermography for Electrosurgical Rate Modulation via Optimization (ThERMO), a closed-loop algorithm that uses real-time thermal imaging data to minimize thermal injury while ensuring accurate cut margins, was tested on ex vivo porcine tissue.
ORIGINAL PAPER
Velocity Optimization via Thermal Imaging Enhances Autonomous Tumor Resection
WHAT WE KNOW
Histological analysis was performed to detect thermal injury extent at a cellular level, and 3D photogrammetric measurement was used to verify margin accuracy. ThERMO's performance was compared against two previously used fixed velocity methods. Results: ThERMO outperformed both fixed velocity comparison methods without requiring data-driven training or iterative tuning, reducing thermal injury by up to 52%, improving cut accuracy by up to 59%, and maintaining task completion speed.
WATCH NEXT
Review the primary source, validate the main result, and establish whether any listed-company transmission is direct.
EVIDENCE
What the evidence supports so far
Research signals
Classification pending.
What remains unverified
The full methodology, effect size, and limitations still require analyst review.